Part Number Hot Search : 
129M2G E101MPD 47K100 603X4 D2SB6 9NF20 AS5043TR 3PMT48A
Product Description
Full Text Search
 

To Download HCC5-6OVP-ACC Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  power-one produces the industry?s broadest selection of linear power supplies with output voltages from 5 volts through 250 volts. rugged technology and proven design merge to create quiet, highly-regulated, dependable dc power. the linear power supplies are approved to domestic and international regulatory standards, and are ce marked to the low voltage directive (lvd). ? worldwide ac input capabilities: 100/120/220/230/240 vac ? 0.05% output regulation ? low output ripple ? ul, csa, and tv approvals ? mean time before failure (mtbf) in excess of 300,000 hours ? ce marked to low voltage directive ? 100% burn-in ? 2 year warranty ? overvoltage protection (ovp) standard on 5v single outputs, optional for other outputs under 48v features linear power supplies data sheet rev. jan 16, 2006 page 1 of 9 www.power-one.com description overvoltage protection options these optional overvoltage protection modules are offered for use with power-one?s linear power supplies. each is user adjustable from 6.4v to 34v. ovp selection guide model case size ovp modules required single b,c,n,d (1) ovp-12 output e,f (1) ovp-24 dual aa,b,bb,cc (1) ovp-12 protects both outputs output e (1) ovp-24 protects both outputs triple aa,baa,d (1) ovp-12 protects both 12v output cbb, 131 through 15v outputs dbb,dcc peak n,baa,cbb current 131, cp340-a (1) ovp-12 protects any output models cp510-a not provided with built-in ovp note: outputs with factory built-in ovp are indicated in the voltage/current rating chart for each model. ovp is not available for 48v through 250v models. ovp-12 ovp-24 overvolt age protection options
rev. jan 16, 2006 page 2 of 9 www.power-one.com linear power supplies data sheet unsigned output voltages are isolated and can be used as either + or - polarities. output output model voltage current (input voltage case additional (vdc) (amps) of 100 to 240vac) type features & notes single output models- 5v to 48vout 5 1.5 ha5-1.5/ovp-a b a 5 3 hb5-3/ovp-a b a, c 5 6 hc5-6/ovp-a c a, c 5 9 hn5-9/ovp-a n a, c 5 12 hd5-12/ovp-a d a, c 5 18 he5-18/ovp-a e a, c 5 25 f5-25/ovp-a f a, c, d, h 5 35 g5-35/ovp-a f a, c, d, h 5 50 cp197-a f a, c, d 12 1.7 hb12-1.7-a b c 12 3.4 hc12-3.4-a c c 12 5.1 hn12-5.1-a n c 12 6.8 hd12-6.8-a d c 12 10.2 he12-10.2-a e c 12 to 15 0.9 ha15-0.9-a b 12 to 15 16 f15-15-a f c, d, h 15 1.5 hb15-1.5-a b c 15 3 hc15-3-a c c 15 4.5 hn15-4.5-a n c 15 6 hd15-6-a d c 15 9 he15-9-a e c 24 1.2 hb24-1.2-a b c 24 2.4 hc24-2.4-a c c 24 3.6 hn24-3.6-a n c 24 4.8 hd24-4.8-a d c 24 7.2 he24-7.2-a e c 24 to 28 0.5 ha24-0.5-a b 24 to 28 12 f24-12-a f c, d, h 28 1 hb28-1-a b c 28 2 hc28-2-a c c 28 3 hn28-3-a n c 28 4 hd28-4-a d c 28 6 he28-6-a e c 48 0.5 hb48-0.5-a b 48 1 hc48-1-a c 48 3 hd48-3-a d c 48 4 he48-4-a e c (see additional features column) a overvoltage protection, set at 6.2 v 0.4 v. b non-adjustable 3-terminal regulator. c remote sense provided. d with output inhibit and parallel operation master/slave capability. e with output inhibit. f adjustable 3-terminal regulator. g can be made into an isolated output by removing jumper w1. h model requires 100 lfm forced-air cooling above 75% of rated output power at 50 degrees c. case dimensions type (inches) aa 6.50 x 4.00 x 2.10 b 4.87 x 4.00 x 2.10 baa 10.25 x 4.00 x 2.95 bb 7.00 x 4.87 x 2.95 c 5.62 x 4.87 x 2.95 cbb 11.00 x 4.87 x 3.28 cc 9.38 x 4.87 x 3.28 cp131 11.00 x 4.87 x 3.28 cp510-a 8.25 x 4.87 x 3.28 d 9.00 x 4.87 x 3.28 dbb 14.25 x 4.87 x 3.38 dcc 15.00 x 4.88 x 4.55 e 14.00 x 4.87 x 3.53 f 16.75 x 4.88 x 5.00 n 7.00 x 4.87 x 3.28 case dimensions type (millimeters) aa 165.10 x 101.60 x 53.34 b 123.70 x 101.60 x 53.34 baa 260.35 x 101.60 x 74.93 bb 177.80 x 123.70 x 74.93 c 142.75 x 123.70 x 74.93 cbb 279.40 x 123.70 x 83.31 cc 238.25 x 123.70 x 83.31 cp131 279.40 x 123.70 x 83.31 cp510-a 209.55 x 123.70 x 83.31 d 228.60 x 123.70 x 83.31 dbb 361.95 x 123.70 x 85.85 dcc 381.00 x 123.95 x 115.57 e 355.60 x 123.70 x 89.66 f 425.50 x 123.95 x 127.00 n 177.80 x 123.70 x 83.31
linear power supplies data sheet rev. jan 16, 2006 page 3 of 9 www.power-one.com dual-output models unsigned output voltages are isolated and can be used as either + or - polarities. (see additional features column) a overvoltage protection, set at 6.2 v 0.4 v. b non-adjustable 3-terminal regulator. c remote sense provided. d with output inhibit and parallel operation master/slave capability. e with output inhibit. f adjustable 3-terminal regulator. g can be made into an isolated output by removing jumper w1. h model requires 100 lfm forced-air cooling above 75% of rated output power at 50 degrees c. case dimensions type (inches) aa 6.50 x 4.00 x 2.10 b 4.87 x 4.00 x 2.10 baa 10.25 x 4.00 x 2.95 bb 7.00 x 4.87 x 2.95 c 5.62 x 4.87 x 2.95 cbb 11.00 x 4.87 x 3.28 cc 9.38 x 4.87 x 3.28 cp131 11.00 x 4.87 x 3.28 cp510-a 8.25 x 4.87 x 3.28 d 9.00 x 4.87 x 3.28 dbb 14.25 x 4.87 x 3.38 dcc 15.00 x 4.88 x 4.55 e 14.00 x 4.87 x 3.53 f 16.75 x 4.88 x 5.00 n 7.00 x 4.87 x 3.28 case dimensions type (millimeters) aa 165.10 x 101.60 x 53.34 b 123.70 x 101.60 x 53.34 baa 260.35 x 101.60 x 74.93 bb 177.80 x 123.70 x 74.93 c 142.75 x 123.70 x 74.93 cbb 279.40 x 123.70 x 83.31 cc 238.25 x 123.70 x 83.31 cp131 279.40 x 123.70 x 83.31 cp510-a 209.55 x 123.70 x 83.31 d 228.60 x 123.70 x 83.31 dbb 361.95 x 123.70 x 85.85 dcc 381.00 x 123.95 x 115.57 e 355.60 x 123.70 x 89.66 f 425.50 x 123.95 x 127.00 n 177.80 x 123.70 x 83.31 model numbers highlighted in yellow or shaded are not recommended for new designs. output output model voltage current (input voltage case additional (vdc) (amps) of 100 to 240vac) type features & notes dual output models- 5v to 15vout +5, ?5 1.5, 1.5 haa5-1.5/ovp-a aa a +5, ?5 3, 3 hbb5-3/ovp-a bb a +5, ?5 6, 6 hcc5-6/ovp-a cc a, c +5, +12 2, 4 cp323-a n a, e +5, +12 6, 2.5 cp510-a cp510-a a 5, 12 to 15 2, 0.5 haa512-a aa a, c 5, 12 to 15 3, 1.25 hbb512-a bb a, c 5, 12 to 15 6, 2.5 hcc512-a cc a, c +12, ?5 1, 0.4 haa15-0.8-a aa c +12, ?5 1.7, 0.7 hbb15-1.5-a bb c +12, ?12 0.4, 0.4 had12-0.4-a b b +12, ?12 1, 1 haa15-0.8-a aa c +12, ?12 1.7, 1.7 hbb15-1.5-a bb c +12, ?12 3.4, 3.4 hcc15-3-a cc c +12, ?12 5, 5 hdd15-5-a e c +12, ?15 1, 0.8 haa15-0.8-a aa c +12, ?15 1.7, 1.5 hbb15-1.5-a bb c +12, ?15 3.4, 3 hcc15-3-a cc c +12, ?15 5, 5 hdd15-5-a e c +15, ?5 0.8, 0.4 haa15-0.8-a aa c +15, ?5 1.5, 0.7 hbb15-1.5-a bb c +15, ?12 0.8, 1 haa15-0.8-a aa c +15, ?12 1.5, 1.7 hbb15-1.5-a bb c +15, ?12 3, 3.4 hcc15-3-a cc c 15, ?12 5, 5 hdd15-5-a e c dual output models- 15v to 24vout +15, ?15 0.4, 0.4 had15-0.4-a b b +15, ?15 0.8, 0.8 haa15-0.8-a aa c +15, ?15 1.5, 1.5 hbb15-1.5-a bb c +15, ?15 3, 3 hcc15-3-a cc c +15, ?15 5, 5 hdd15-5-a e c +18 to +20, ?18 to ?20 0.4, 0.4 haa24-0.6-a aa +18 to +20, ?18 to ?20 0.9, 0.9 hbb24-1.2-a bb +18 to +20, ?18 to ?20 1.8, 1.8 hcc24-2.4-a cc c +18 to +20, ?24 0.4, 0.6 haa24-0.6-a aa +18 to +20, ?24 0.9, 1.2 hbb24-1.2-a bb +18 to +20, ?24 1.8, 2.4 hcc24-2.4-a cc c +24, ?18 to ?20 0.6, 0.4 haa24-0.6-a aa +24, ?18 to ?20 1.2, 0.9 hbb24-1.2-a bb +24, ?18 to ?20 2.4, 1.8 hcc24-2.4-a cc c +24, ?24 0.6, 0.6 haa24-0.6-a aa +24, ?24 1.2, 1.2 hbb24-1.2-a bb +24, ?24 2.4, 2.4 hcc24-2.4-a cc c
rev. jan 16, 2006 page 4 of 9 www.power-one.com linear power supplies data sheet unsigned output voltages are isolated and can be used as either + or - polarities. (see additional features column) a overvoltage protection, set at 6.2 v 0.4 v. b non-adjustable 3-terminal regulator. c remote sense provided. d with output inhibit and parallel operation master/slave capability. e with output inhibit. f adjustable 3-terminal regulator. g can be made into an isolated output by removing jumper w1. h model requires 100 lfm forced-air cooling above 75% of rated output power at 50 degrees c. case dimensions type (inches) aa 6.50 x 4.00 x 2.10 b 4.87 x 4.00 x 2.10 baa 10.25 x 4.00 x 2.95 bb 7.00 x 4.87 x 2.95 c 5.62 x 4.87 x 2.95 cbb 11.00 x 4.87 x 3.28 cc 9.38 x 4.87 x 3.28 cp131 11.00 x 4.87 x 3.28 cp510-a 8.25 x 4.87 x 3.28 d 9.00 x 4.87 x 3.28 dbb 14.25 x 4.87 x 3.38 dcc 15.00 x 4.88 x 4.55 e 14.00 x 4.87 x 3.53 f 16.75 x 4.88 x 5.00 n 7.00 x 4.87 x 3.28 case dimensions type (millimeters) aa 165.10 x 101.60 x 53.34 b 123.70 x 101.60 x 53.34 baa 260.35 x 101.60 x 74.93 bb 177.80 x 123.70 x 74.93 c 142.75 x 123.70 x 74.93 cbb 279.40 x 123.70 x 83.31 cc 238.25 x 123.70 x 83.31 cp131 279.40 x 123.70 x 83.31 cp510-a 209.55 x 123.70 x 83.31 d 228.60 x 123.70 x 83.31 dbb 361.95 x 123.70 x 85.85 dcc 381.00 x 123.95 x 115.57 e 355.60 x 123.70 x 89.66 f 425.50 x 123.95 x 127.00 n 177.80 x 123.70 x 83.31 model numbers highlighted in yellow or shaded are not recommended for new designs. output output model (input voltage current voltage of case additional features) (vdc) (amps) 100 to 240vac) type & notes triple output models- 5v to 24vout +5, ?5, 24 6, 1.2, 3.5 cp379-a cp131 a, c, f, g 5, +12, ?5 3, 1, 0.4 hbaa-40w-a baa a, c +5, +12 to +15, ?5 6, 1, 0.4 hcaa-60w-a d a, c +5, +12, 5 6, 5, 0.25 cp498-a cp131 a, c, f 5, +12, ?5 8, 1.7, 0.7 cp131-a cp131 a, c 5, +12, ?5 12, 1.7, 0.7 hdbb-105w-a dbb a, c 5, +12 to +15, ?5 2, 0.4, 0.4 htaa-16w-a aa a 5, +12, ?5 6, 1.7, 0.7 hcbb-75w-a cbb c 5, +12, ?12 3, 1, 1 hbaa-40w-a baa a, c +5, +12 to +15, ?12 to ?15 6, 1, 1 hcaa-60w-a d a, c +5, +12, 12 6, 5, 0.5 cp498-a cp131 a, c, f 5, +12, ?12 6, 1.7, 1.7 hcbb-75w-a cbb c 5, +12, ?12 8, 1.7, 1.7 cp131-a cp131 a, c 5, +12, ?12 12, 1.7, 1.7 hdbb-105w-a dbb c 5, +12 to +15, ?12 to ?15 2, 0.4, 0.4 htaa-16w-a aa a 5, +12, ?12 12, 3.4, 3.4 hdcc-150w-a dcc a, c 5, +12, ?15 3, 1, 0.8 hbaa-40w-a baa a, c 5, +12, ?15 6, 1.7, 1.5 hcbb-75w-a cbb c 5, +12, ?15 8, 1.7, 1.5 cp131-a cp131 a, c 5, +12, ?15 12, 1.7, 1.5 hdbb-105w-a dbb c 5, +12, ?15 12, 3.4, 3 hdcc-150w-a dcc a, c +5, ?12, 24 6, 1.2, 3.5 cp379-a cp131 a, c, f, g 5, +15, ?5 3, 0.8, 0.4 hbaa-40w-a baa a, c 5, +15, ?5 6, 1.5, 0.7 hcbb-75w-a cbb c 5, +15, ?5 8, 1.5, 0.7 cp131-a cp131 a, 5, +15, ?5 12, 1.5, 0.7 hdbb-105w-a dbb c 5, +15, ?12 3, 0.8, 1 hbaa-40w-a baa a, c 5, +15, ?12 6, 1.5, 1.7 hcbb-75w-a cbb c 5, +15, ?12 8, 1.5, 1.7 cp131-a cp131 a, c 5, +15, ?12 12, 1.5, 1.7 hdbb-105w-a dbb c 5, +15, ?12 12, 3, 3.4 hdcc-150w-a dcc a, c 5, +15, ?15 3, 0.8, 0.8 hbaa-40w-a baa a, c 5, +15, ?15 6, 1.5, 1.5 hcbb-75w-a cbb c 5, +15, ?15 8, 1.5, 1.5 cp131-a cp131 a, c 5, +15, ?15 12, 1.5, 1.5 hdbb-105w-a dbb c 5, +15, ?15 12, 3, 3 hdcc-150w-a dcc a, c quad output models- 5v to 24vout models +5, +12, ?5, +24 6, 1, 0.5, 2.4 cp503-a cp131 a, h +5, +12, ?12, +24 6, 1, 1, 2.4 cp503-a cp131 a, h
linear power supplies data sheet rev. jan 16, 2006 page 5 of 9 www.power-one.com input specifications parameter conditions/description min nom max units input voltage - ac jumper selectable, shipped factory configured for 100 vac tap 87 100 110 (note 1, 2) 120vac operation. all models must be externally 120 vac tap 104 120 132 vac fused for proper operation. fuse ratings are marked 220 vac tap 191 220 242 on each unit. consult factory for each unit?s fuse 240 vac tap 209 240 264 requirements. input frequency ac input. 47 63 hz line regulation output voltage charge for a 10% line change: f case models. -0.01 +0.01 had12, had15. -1.0 +1.0 % outputs with adjustable three terminal regulators. -0.5 +0.5 all other models. -0.05 +0.05 notes: 1) derate output current 10% for 50hz operation. 2) input voltage tolerance for 230vac operation is +15%, -10%. output specifications parameter conditions/description min nom max units output adjustment minimum output adjustment range (note 1). -5 +5 % efficiency 5 volt outputs. 45 12 volt and 15 volt outputs. 55 % 24 volt and higher outputs. 60 f case models. 3.0 mv pk-pk ripple and noise 5 volt, 12 volt, and 15 volt models. 5.0 mv pk-pk (note 2) all three terminal regulator outputs. 0.2 % pk-pk 24 volt through 250 volt models. 3.0mv pk-pk plus 0.02% of output voltage, max load regulation output change for a 50% load change: f case models. -0.02 +0.02 had12, had15. -1 +1 % outputs with adjustable three terminal regulators. -0.5 +0.5 all other models. -0.05 +0.05 transient response recovery time, to within 1% of initial set point due to a 50% load change. 50 s notes: 1) output voltage adjustments: output voltage adjustments can be made to within 5% of nominal voltage. locate the ?vadj? potentiometer on the power supply pcb and use a screwdriver to adjust the output pot. the had12 and had15 3-terminal regulator outputs are not adjustable . 2) full load, 20mhz bandwidth. safety, regulatory, and emi specifications parameter conditions/description min nom max units agency approvals ul60950 3rd edition. csa 60950 3rd edition. approved en60950 3rd edition. iec60950 3rd edition dielectric withstand input to output. 3750 v rms voltage input to ground. 3750 electromagnetic fcc cfr title 47 part 15 sub-part b - conducted. interference en55022 / cispr 22 conducted. compatible with system compliance to level b. en55022 / cispr 22 radiated. leakage current per en60950 (264vac) 23 50 a interface signals and internal protection parameter conditions/description min nom max units overvoltage protection provided on 5 volt output units where indicated. 5.8 6.6 v other outputs may use optional overvoltage protectors ovp-12 and ovp-24. remote sense total voltage compensation for cable losses with respect to the main output. 250 mv provided on models where indicated. overcurrent/short circuit automatic current limit/foldback. rated as a percentage of output power. 115 120 140 % protection master/slave operation for parallel operation of up to 6 units. master/slave pin provided on f case models only. contact factor y for application notes.
rev. jan 16, 2006 page 6 of 9 www.power-one.com linear power supplies data sheet environmental specifications parameter conditions/description min nom max units operating temperature derate output power linearly above 50c by 3% per c. at 100% load 0 50 c at 40% load 70 c storage temperature -40 85 c temperature coefficient 0c to 50c (after 15 minute warm-up). 0.1 0.3 %/c 24 hours after warm-up. -0.3 +0.3 % shock operating. 20 g pk vibration random vibration from 10 hz to 2 khz, 3 axis. 6.15 g rms relative humidity non-condensing. 5 95 %rh
linear power supplies data sheet rev. jan 16, 2006 page 7 of 9 www.power-one.com
rev. jan 16, 2006 page 8 of 9 www.power-one.com linear power supplies data sheet
linear power supplies data sheet rev. jan 16, 2006 page 9 of 9 www.power-one.com nuclear and medical applications - power-one products are not designed, intended for use in, or authorized for use as critical c omponents in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written conse nt of the respective divisional president of power-one, inc. technical revisions - the appearance of products, including safety agency certifications pictured on labels, may change dependin g on the date manufactured. specifications are subject to change without notice.


▲Up To Search▲   

 
Price & Availability of HCC5-6OVP-ACC

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X